Un viaje entre libros  Ver más

Enviar a
Provincia de Madrid
0
  • argentina
  • chile
  • colombia
  • españa
  • méxico
  • perú
  • estados unidos
  • internacional

Selecciona tu país

América

Europa

Resto del mundo

portada Chemical Fume Hood Testing Improvements Needed to Reduce Health and Safety Risk to EPA Employess (en Inglés)
Formato
Libro Físico
Editorial
Idioma
Inglés
N° páginas
30
Encuadernación
Tapa Blanda
Dimensiones
28.0 x 21.6 x 0.2 cm
Peso
0.10 kg.
ISBN13
9781500640729

Chemical Fume Hood Testing Improvements Needed to Reduce Health and Safety Risk to EPA Employess (en Inglés)

Agency, U. S. Environmental Protection (Autor) · Createspace · Tapa Blanda

Chemical Fume Hood Testing Improvements Needed to Reduce Health and Safety Risk to EPA Employess (en Inglés) - Agency, U. S. Environmental Protection

Libro Nuevo Importado
Envío: 15 a 20 días háb.
29,05 €26,15 €
-10%
Libro Nuevo

Quedan más de 100 unidades

26,15 €
Llega entre el 10 Ago y el 19 Ago a Provincia de Madrid. Seleccionar ubicación

Reseña del libro "Chemical Fume Hood Testing Improvements Needed to Reduce Health and Safety Risk to EPA Employess (en Inglés)"

We found that the EPA complied with applicable regulations and guidance in procuring both the chemical fume hood retrofit kits and fume hood testing contracts. The EPA awarded both contracts using competition as opposed to using sole source procurement contracting methods. However, the same subcontractor, operating under the same prime contractor, is performing both the retrofitting of the chemical fume hoods and the annual testing of the hoods, which presents a potential conflict of interest. The agency already completed corrective action in response to our preliminary recommendation for this finding. In addition, our technical expert's review of a sample of testing results for the chemical fume hoods raises numerous concerns with the way the testing was performed at the EPA's Research Triangle Park laboratories. The subcontractor rated the hoods as pass: When not all of the EPA requirements were met. When controllers or monitors were not functional. When the testing results did not include all required documentation. The agency's 2009 testing protocol spells out the criteria for testing and evaluating the performance of fume hoods at the EPA's laboratories, and would also be applicable to fume hood retrofitting. The EPA relied on the prime contractor to ensure the subcontractor's fume hood testing met all requirements, and did not retest any of the hoods, without a user's specific report of a problem. As a result, the EPA has limited assurance as to the safety of the chemical fume hoods, and there is a risk to the health and safety of the laboratory workers.

Opiniones del libro

Preguntas frecuentes sobre el libro

Todos los libros de nuestro catálogo son Originales.
El libro está escrito en Inglés.
La encuadernación de esta edición es Tapa Blanda.

Preguntas y respuestas sobre el libro

¿Tienes una pregunta sobre el libro? Inicia sesión para poder agregar tu propia pregunta.

Opiniones sobre Buscalibre

Ver más opiniones de clientes