¡Envío gratis y en 1 día!* a Península + 5% dcto  ¡Ver más!

menú

0
  • argentina
  • chile
  • colombia
  • españa
  • méxico
  • perú
  • estados unidos
  • internacional
portada Vacuum Drop Test of Air-Cooled Condensers in Operation (en Inglés)
Formato
Libro Físico
Editorial
Idioma
Inglés
N° páginas
24
Encuadernación
Tapa Blanda
Dimensiones
21.0 x 14.8 x 0.2 cm
Peso
0.05 kg.
ISBN13
9783668688261

Vacuum Drop Test of Air-Cooled Condensers in Operation (en Inglés)

Hans Georg Schrey (Autor) · Grin Verlag · Tapa Blanda

Vacuum Drop Test of Air-Cooled Condensers in Operation (en Inglés) - Schrey, Hans Georg

Libro Físico

45,83 €

48,25 €

Ahorras: 2,41 €

5% descuento
  • Estado: Nuevo
  • Quedan 98 unidades
Origen: Estados Unidos (Costos de importación incluídos en el precio)
Se enviará desde nuestra bodega entre el Miércoles 19 de Junio y el Lunes 08 de Julio.
Lo recibirás en cualquier lugar de España entre 1 y 5 días hábiles luego del envío.

Reseña del libro "Vacuum Drop Test of Air-Cooled Condensers in Operation (en Inglés)"

Scientific Essay from the year 2018 in the subject Physics - Thermodynamics, language: English, abstract: Vacuum tightness is critical for air-cooled condensers operating at low absolute pressure. Low vacuum is aimed for because vacuum dominates the power plant efficiency. To verify vacuum tightness usually a vacuum drop test is made with the system empty at normal atmospheric temperature and free of any liquids. This test is done before commissioning of the power unit and generally follows the recommendations of the Heat Exchanger Institute (HEI) as outlined in 6.1.1 of "Standards for Steam Jet Vacuum Systems". However, over time of operation the power plant may develop leakages, which were not present at the time of the original drop test. This calls for a tightness test at operating conditions where pre-conditions for the standard vacuum drop test are not fulfilled. The report describes a vacuum drop test without interfering too much into normal power plant operation. The test is suitable for stationary operating conditions using standard operation readings. The assessment of leakage flow is based on the measured vacuum decay rate. It is shown that vacuum decay rates taken from tests before and after commissioning are different. Contractual fixing of acceptable vacuum decay rates should therefore be treated with care. Example graphs for easy evaluation are given.

Opiniones del libro

Ver más opiniones de clientes
  • 0% (0)
  • 0% (0)
  • 0% (0)
  • 0% (0)
  • 0% (0)

Preguntas frecuentes sobre el libro

Todos los libros de nuestro catálogo son Originales.
El libro está escrito en Inglés.
La encuadernación de esta edición es Tapa Blanda.

Preguntas y respuestas sobre el libro

¿Tienes una pregunta sobre el libro? Inicia sesión para poder agregar tu propia pregunta.

Opiniones sobre Buscalibre

Ver más opiniones de clientes